aboutsummaryrefslogtreecommitdiff
path: root/src/GRHydro_C2P2C.F90
blob: 1ce1347a4a05e4cd94b384fba65d218bfdc64f1f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
 /*@@
   @file      GRHydro_C2P2C.F90
   @date      Sat Jan 26 02:44:43 2002
   @author    Luca Baiotti
   @desc 
   A test of the conservative <--> primitive variable exchange
   @enddesc 
 @@*/

#include "cctk.h"
#include "cctk_Parameters.h"
#include "cctk_Arguments.h"

 /*@@
   @routine    c2p2c
   @date       Sat Jan 26 02:45:19 2002
   @author     Luca Baiotti
   @desc 
   Testing the conservative <--> primitive variable transformations.
   The values before and after should match.
   @enddesc 
   @calls     
   @calledby   
   @history 
 
   @endhistory 

@@*/

subroutine c2p2c(CCTK_ARGUMENTS)

  implicit none

  DECLARE_CCTK_ARGUMENTS
  DECLARE_CCTK_PARAMETERS

#if !USE_EOS_OMNI
#ifdef _EOS_BASE_INC_
#undef _EOS_BASE_INC_
#endif
#include "EOS_Base.inc"
#endif

  integer didit,i,j,k,nx,ny,nz
  CCTK_REAL det
  CCTK_REAL uxx,uxy,uxz,uyy,uyz,uzz
  CCTK_REAL gxx_send,gxy_send,gxz_send,gyy_send,gyz_send,gzz_send
  CCTK_REAL dens_send,sx_send,sy_send,sz_send,tau_send
  CCTK_REAL rho_send,velx_send,vely_send,velz_send,eps_send
  CCTK_REAL press_send,w_lorentz_send,x_send,y_send,z_send,r_send
  CCTK_REAL pmin, epsmin
  CCTK_INT C2P_failed
  logical epsnegative

#if USE_EOS_OMNI
! begin EOS Omni vars
  integer :: n = 1
  integer :: keytemp = 0
  integer :: anyerr = 0
  integer :: keyerr(1) = 0
  real*8  :: xpress = 0.0d0
  real*8  :: xeps = 0.0d0
  real*8  :: xtemp = 0.0d0
  real*8  :: xye = 0.0d0
! end EOS Omni vars
#endif

  call CCTK_WARN(1,"This test works only with Ideal_Fluid EoS")

  nx = cctk_lsh(1)
  ny = cctk_lsh(2)
  nz = cctk_lsh(3)
  
  x_send = 0.0d0
  y_send = 0.0d0
  z_send = 0.0d0
  r_send = 0.0d0
  
  gxx_send = 1.0d0
  gyy_send = 1.0d0 
  gzz_send = 1.0d0
  gxy_send = 0.0d0
  gxz_send = 0.0d0
  gyz_send = 0.0d0
  
  det = 1.0d0
  
  uxx = 1.0d0
  uyy = 1.0d0 
  uzz = 1.0d0
  uxy = 0.0d0
  uxz = 0.0d0
  uyz = 0.0d0
  
  dens_send = 1.29047362d0
  sx_send   = 0.166666658d0
  sy_send   = 0.166666658d0
  sz_send   = 0.166666658d0
  tau_send  = 0.484123939d0
  
  eps_send = 1.0d-6
  press_send = 6.666666666666667d-7
  w_lorentz_send = 1.0d0

  epsnegative = .false.
  
  GRHydro_rho_min = 1.e-10
#if USE_EOS_OMNI
  call EOS_Omni_press(GRHydro_eos_handle,keytemp,n,&
       GRHydro_rho_min,1.0d0,xtemp,xye,pmin,keyerr,anyerr)

  call EOS_Omni_EpsFromPress(GRHydro_eos_handle,keytemp,n,&
       GRHydro_rho_min,xeps,xtemp,xye,pmin,epsmin,keyerr,anyerr)
#else
  pmin   = EOS_Pressure(GRHydro_eos_handle, GRHydro_rho_min, 1.0d0)
  epsmin = EOS_SpecificIntEnergy(GRHydro_eos_handle, GRHydro_rho_min, pmin)
#endif
  C2P_failed = 0

  write(*,*) 'C2P2C test: initial values.'
  write(*,*) '   conservative variables: '
  write(*,*) '   dens: ',dens_send
  write(*,*) '   sx  : ',sx_send
  write(*,*) '   sy  : ',sy_send
  write(*,*) '   sz  : ',sz_send
  write(*,*) '   tau : ',tau_send
  write(*,*) '   eps : ',eps_send
  write(*,*) '   W   : ',w_lorentz_send
  
  write(*,*) 'C2P2C test: getting the associated primitive variables.'
  call Con2Prim_pt(GRHydro_eos_handle,dens_send,sx_send,sy_send,sz_send, &
       tau_send,rho_send,velx_send,vely_send,velz_send, &
       eps_send,press_send,w_lorentz_send, &
       uxx,uxy,uxz,uyy,uyz,uzz,det,x_send,y_send,z_send,r_send,&
       epsnegative,GRHydro_rho_min, pmin, epsmin, GRHydro_init_data_reflevel,C2P_failed)
  
  write(*,*) 'C2P2C test: the primitive variables are'
  write(*,*) '   primitive variables: '
  write(*,*) '   rho   : ',rho_send
  write(*,*) '   velx  : ',velx_send
  write(*,*) '   vely  : ',vely_send
  write(*,*) '   velz  : ',velz_send
  write(*,*) '   press : ',press_send
  write(*,*) '   eps   : ',eps_send
  write(*,*) '   W     : ',w_lorentz_send
  
  write(*,*) 'C2P2C test: converting back to conserved variables.'
  call prim2con(GRHydro_eos_handle,gxx_send, gxy_send, gxz_send, gyy_send, gyz_send, gzz_send, det, &
       dens_send, sx_send, sy_send, sz_send, tau_send, rho_send, &
       velx_send, vely_send, velz_send, eps_send, press_send, w_lorentz_send) 
  
  write(*,*) 'C2P2C test: the conserved variables are'
  write(*,*) '   conservative variables: '
  write(*,*) '   dens: ',dens_send
  write(*,*) '   sx  : ',sx_send
  write(*,*) '   sy  : ',sy_send
  write(*,*) '   sz  : ',sz_send
  write(*,*) '   tau : ',tau_send
  write(*,*) '   eps : ',eps_send
  write(*,*) '   W   : ',w_lorentz_send
  
  STOP

  return

end subroutine c2p2c